WRNK-391-02 armored thermocouple




Product Name: WRNK-391-02 Armored Thermocouple
Number of products: 134838-792
Product model: WRNK-391-02
Updated: 2009.07.01
Produced by: Thermocouple Thermocouple, thermal resistance, bimetal thermometer, polytetrafluoroethylene, tetrafluorogasket--Shanghai Feilong Instrument & Electrical Co., Ltd. Customized: Can be customized according to customer needs
Product details
WRNK armored thermocouple





Thermocouple model, index number and recommended temperature for different materials and diameters

Electrode material model Index number Housing material Shell diameter (mm) Recommended temperature ℃
Long-term use maximum temperature Short-term maximum temperature
Nichrome--NiSi   WRKK K GH3030 0.25; 300 600
NiCr-NiSi (WRNK) 0.5; 1.0 500
1.5; 2.0; 3.0 800 900
4.0; 4.5; 5.0 900 1000
6.0; 8.0 1000 1100
1Cr18Ni9Ti 0.25; 300 600
0.5; 1.0 400
1.5; 2.0 600 700
3.0; 4.0; 4.5 800 900
5.0; 6.0; 8.0
NiCrSi--NiSi   WRNK N GH3030 0.25; 300 600
NiCrSi-NiSi (WRMK) 0.5; 1.0 500
1.5; 2.0; 3.0 800 900
4.0; 4.5; 5.0 900 1100
6.0; 8.0 1000 1200
1Cr18Ni9Ti 0.25; 300 600
0.5; 1.0 500
1.5; 2.0 600 700
3.0; 4.0; 4.5 800 900
5.0; 6.0; 8.0
Nickel chromium--copper nickel   WREK E 1Cr18Ni9Ti 0.5; 1.0 400 500
NiCr-CuNi 1.5; 2.0; 500 600
3.0; 4.0; 4.5; 5.0 600 700
6.0; 8.0 700 800
Iron--copper nickel   WRJK J 1Cr18Ni9Ti 0.5; 1.0 300 400
Fe-CuNi (WRFK) 1.5; 2.0; 400 500
3.0; 4.0; 4.5; 5.0 500 600
6.0; 8.0 600 750
Copper--copper nickel   WRTK T 1Cr18Ni9Ti 0.5; 1.0 200 250
-C u Ni C u -C u Ni (WRCK) 1.5; 2.0; 3.0; 4.0 250 300
4.5; 5.0
6.0; 8.0 300 350
--铂 Platinum Rhodium 10 -Platinum   WRSK S GH3030 2.0; 1000 1050
Rh 10 -P t P t Rh 10 -P t (WRPK) 3.0; 4.0; 4.5 1100 1200
5.0; 6.0; 8.0
--铂 Platinum Rhodium 13 -Platinum   WRRK R GH3030 2.0; 1000 1100
Rh 13 -P t P t Rh 13 -P t (WRQK) 3.0; 4.0; 4.5 1100 1200
5.0; 6.0; 8.0
--铂铑 6 Platinum Rhodium 30 -Platinum Rhodium 6 WRBK B GH3030 2.0; 1000 1050
Rh 30 -P t Rh 6 P t Rh 30 -P t Rh 6 (WRRK) 3.0; 4.0; 4.5 1100 1200


* The model numbers in parentheses in the model number column are the methods used in the past.

● Temperature measurement range and accuracy of commonly used armored thermocouples (grade Ⅱ)


Index number Temperature measurement range (℃) Tolerance (reference temperature is 0 ℃)
K, N -40 ~ 1100 ± 2.5 ℃ or ± 0.0075∣t∣
E -40 ~ 800
J -40 ~ 750
T -40 ~ 350 ± 1.0 ℃ or ± 0.0075∣t∣
Note: "t" is the measured temperature; the greater of the two tolerance values given in the same column.

● When the thermal response time of the armored thermocouple changes stepwise, the time required for the output value of the thermocouple to change to a specified percentage of the step change is called the thermal response time, which is expressed by τ (taken 50% is represented by τ0.5).


Thermal response time of armored thermocouple


0.5 (秒) Thermal response time τ 0.5 (seconds)
Casing diameter d (mm) Shell type (≤) Insulated (≤)
2 0.4 0.5
3 0.6 1.2
4 0.8 2.5
5 1.2 4
6 2 6
8 4 8


● Insulation resistance
When the ambient air temperature is 20 ± 15 ° C and the relative humidity is not more than 80%, the insulation resistance value between the thermal electrode of the insulated armored thermocouple and the outer tube should comply with the following table:

Armored couple diameter D (mm) Test voltage DCV Insulation resistance MΩ · m
0.25 50 ± 5 ≥100
0.5 ~ 1.5 50 ± 5 ≥1000
﹥ 1.5 500 ± 50 ≥1000


Note: The insulation resistance is expressed by MΩ · m, which is the product of the insulation resistance at room temperature and the length of the armored couple.
For example: 1000MΩ · m means: the insulation resistance of a 1m sample is
1000MΩ, the insulation resistance of the 10m sample is 100MΩ.
For armored couples with a length less than 1m, it is calculated as 1m.
Socket-type junction boxes and armored thermocouples with compensation leads are not included in this example.


□ Basic Structure of Armored Thermocouple
Armored thermocouples are mainly composed of junction boxes, terminal blocks, and armored thermocouple elements, and are equipped with various mounting fixtures.


● Mounting type:
The fixture is intended for user installation. There are five types of armored thermocouples: no fixed device, fixed ferrule type, movable ferrule type, fixed flange type, and movable flange type. The fixed card type is only for one-time fixed use, and the movable card type can be used for multiple fixed uses.


Ferrule thread (unit: mm)


Card sleeve threaded joint size
Protection tube diameter > 4 ≤4
M M16 × 1.5 M12 × 1.5
S twenty two 19
Ferrule flange (unit: mm)

● Armored thermocouple reference terminal type
The junction box is used to connect the reference terminal of the thermocouple and the display instrument. There are a variety of structural types, such as simple type, splash-proof type, waterproof type, flameproof type, small junction box type, plug-in type, and compensation lead type.
Schematic (partial):


□ Different combinations and ordering instructions of armored thermocouples
The following shows the naming methods of different combinations of different mounting and fixing types and different reference ends. Refer to these combinations as well as the previous "Model Meaning" and "Armored Thermocouple Examples" to easily name the thermocouple you need.
The figure below also indicates the thermocouple length L and sleeve diameter d that should be noted when ordering. When ordering and naming, the use of 1Cr18Ni9Ti stainless steel casing, single type, class II thermocouple need not be specified separately.


● Thermocouple installation method


First, the installation method on the curved pipe Second, the installation method of the inclined pipe through axis





Third, the installation method of the vertical pipe through axis Fourth, the sealing installation method in the boiler flue



















24-hour consultation hotline:
13671774687
Home Flying Dragon Thermocouple Thermocouple products Honor technical standard Thermocouple Information Download Center Leave message contact us Sitemap xml map
General Manager: Manager Xie Mobile: 13671774687 Address: No. 268 West Qufu Road, Shanghai Landline: 021-63811027 Fax: 021-63801621 Email: jimmy011@126.com
© 2018 Shanghai Feilong Instrument Electric Co., Ltd. All rights reserved
online service