TD / TE series electronic regulator




.



Product Name: TD / TE Series Electronic Regulators Product Number: 233753-472
Product model: 0
Updated: 2009.06.13
Manufacturer: Thermocouple--Shanghai Feilong Instrument Electric Co., Ltd.


Product details Product name: TD / TE series electronic regulator, temperature control instrument


Alias: temperature control instrument manufacturer, temperature controller, which is good, temperature controller pointer type, temperature controller factory,


Intelligent temperature control meter, digital temperature controller, portable temperature controller, small temperature controller.


TD / TE series electronic regulator




I. scope of application
TDA / TDW / TEA / TED / TE96 and TE48 series electronic temperature indication regulators are new automation instruments produced by our company. The product is small in size, light in weight, beautiful in appearance, good in reliability, strong in anti-vibration and anti-interference, and the instrument equipped with a thermocouple has a function of automatic cold and cold compensation. Special orders can be added with an over-temperature alarm function. Among them, the installation opening size of the TDW series of instruments is the same as that of the series of dynamic instruments, and it is a replacement product of the XC series of instruments. Can be widely used in metallurgy, plastic machinery, rubber machinery, packaging machinery, clothing, food, printing and dyeing industries, temperature measurement and automatic control in the range of -50 ℃ -1600 ℃


Instrument category

Variety series Display method Regulation Original temperature
TDA Code significance Code significance Code significance
TDW
0 Deviation indication 0 Two position switch 1 Thermocouple
TE72 2 Full range indication 3 Event ratio 2 Thermocouple
4 No instructions 6 Two-bit pulse output
TE96 8 Full range indication
(For TDA only)
Third, the main technical parameters

TDA— TDw— TDB— TEA— TED— TE WRZK
8001 2001 2001 4001 2001 4001
8002 2002 2002 4002 2002 4002
type
8301 2301 301 2301 4301 2301 4301 -1 2001
number 8302 2302 2302 4302 2302 4302 -2 2301
8311 2311 2311 4311 2311 4311
8312 2312 2312 4312 2312 4312
input signal Thermocouple (xxxl type) Thermal resistance (xxx2 type)
Full-scale pointer indicator Full-scale pointer indicator Full-scale pointer indicator
Visual way Full-scale pointer indicator Deviation indication On-off indication On-off indication
Two-position adjustment (xxOx type) Time proportional adjustment (X3xx type)
Adjustment method
Over-limit alarm (xxlx type) Relay output contact capacity 3A 220V 10A 128V
Accuracy class 1.5 level 2.5 level
Temperature measurement range Matching thermocouple (xxxl type) -50 ℃ -1600 ℃
Equipped with thermal resistance (xxx2 type) -200 ℃ -800 ℃
Dimensions 50X120X150 160X80X150 48X 96x120 96X96X142 72X 72x135 48X48X 120 90x180x90
Note: TDA split hole size is the same as TDA-8002
Fourth, the use of the meter is determined by the temperature sensor
Temperature sensor Index number Display and adjustment range (℃) Replaces rhodium graduation number *
Nichrome-copper nickel thermocouple E 0-200; O-300; 0-400; O-500; O-800 EA-2
Nichrome-NiSi thermocouple K O-600; O-8OO; O-1300 EU-2
Platinum rhodium-platinum thermocouple S O ~ 1600 LB-3
Copper thermal resistance Cu50 0-50; 0-100; O-150; -50-150 G
Platinum thermal resistance PtlOO O-100; O-300; -200-1000, etc. BAlBA2
V. Main technical performance
1. Setting error: less than full range: 1.5%


2. Design range: 0-100%,

3. Display accuracy: less than: 2.5%

4. Switching difference is less than: t≤0.75%


5. Time proportion adjustment: (1) Proportional band 3% -6% (2) Cycle time

40 ± 10S


6. Output contact capacity: AC 220V, 3A (resistive) or 1A (inductive)


7. Power supply: 220 ± 10%, 50HZ


8. Working environment: non-corrosive at a temperature of -10 ~ 50 ℃ and a relative temperature exceeding 85%

Sexual gas occasions


9. Dimensions (mm):

TDA: 120X60X150 TDW: 80X160X150

TE72: 72X72X150 TE96: 96X96X 150

TE48: 48X48X 120
Product map

1.TDA-8001 horizontal



2.TDA-8002



3.TDB-0301



4.TDW-2001

、TEA-2001 5 , TEA-2001



6, TED-2001







24-hour consultation hotline:
13671774687
Home Flying Dragon Thermocouple Thermocouple products Honor technical standard Thermocouple Information Download Center Leave message contact us Sitemap xml map
General Manager: Manager Xie Mobile: 13671774687 Address: No. 268 West Qufu Road, Shanghai Landline: 021-63811027 Fax: 021-63801621 Email: jimmy011@126.com
© 2018 Shanghai Feilong Instrument Electric Co., Ltd. All rights reserved
online service