FL102-SD Sanitary Gauge Pressure Transmitter




.

Product name: FL102-SD Sanitary Gauge Pressure Transmitter
Number of products: 105823-734
Product model: FL102-SD
Updated: 2017.09.14
Manufacturer: [Thermocouple, Thermocouple]-Shanghai Feilong Instrument & Electrical Co., Ltd.


Product details
FL102 / 3-D sanitary gauge pressure / absolute pressure transmitter is used to measure the liquid level, density or pressure of liquid, gas or steam, and then convert it into a current signal output of 4 ~ 20mADC.


Standard specifications (adjust the measuring range based on the standard zero point, stainless steel 316L diaphragm, filling fluid is silicone oil)
1. Performance specifications


Reference accuracy of range adjustment: ± 0.25%
Return difference: ≤ 0.15% FS
Repeatability: ≤0.15% FS
Zero drift: <0.15% FS
Thermal hysteresis: <0.1% FS


Ambient temperature affects temperature compensation range: 0 ~ 80 ℃;
Zero point: <0.025% ℃
Range <0.025% ℃
Over-range effect: ± 0.15% xSpan
Stability: ± 0.5% xSpan / 3 years Power effect: ± (0.005% / 10V (12-42V DC)
2.Functional specifications

Influence of installation position


The change of the installation position parallel to the diaphragm surface will not cause zero drift. If the installation position and the diaphragm surface change by more than 90 °, there will be a zero position impact in the range of <0.15kPa, and the range will not be affected.


Output


2-wire system, 4 ~ 20mADC, can teach 485 communication.


Output signal limit: 1min = 3.8mA, lmax = 22mA


Response time: <0.2s
Warm-up time: <15s
Ambient temperature: -20 ~ 100 ℃
Storage temperature / transport temperature: -40 ~ 125 ℃


Medium temperature: -30 ~ 120 ℃
Pressure limit: from vacuum to maximum range.


Overload limit:

3.Installation


Power and load conditions:


Power supply voltage is 24V, R 矣 (Us-12V) / lmax kQ,
Where lmax = 23mA
Maximum power supply voltage: 36VDC
Minimum power supply voltage: 10VDC



Electrical connections


Hessman connector, terminal block is suitable for 0.5 ~ 2.5mm2 wire.


Process connection:


Standard process connection: DN25 / DN40 / DN50 sanitary interface.


4.Physical specifications


Texture


Diaphragm: stainless steel 316L, Hastelloy



5.Model and specification code table


Selection of Sanitary Gauge Pressure Transmitter FL102-S
Selection of sanitary absolute pressure transmitter FL103-S


1 2


Accuracy


D basic error ± 0.25%


⑴ [2]


Gauge pressure
C1 0-0.25 bar
C2 0-0.4 bar
C3 0-0.6 bar
D1 0-1 bar
D2 0-1.6 bar
D3 0-2.5 bar


F1 0-4 bar
F2 0-6 bar
F3 0-10 bar
F4 0-16 bar
F5 0-25 bar
F6 0-30 bar
C5 -1-1.6 bar
D4 -1 -0.6 bar
D5 -1-1.6 bar
F8 -1-3 bar
F9 -1-5 bar
FA -1-9 bar
FB -1-15 bar
FC -1 -24 bar
FD -1 -29 bar
SG special gauge pressure M range absolute pressure ER103-SD
M1 0-1.0 bar
M2 0-1.6bar
M3 0-2.5 bar


01 0-4 bar


02 0-6bar


03 0-10 bar


04 0-16 bar


05 0-25 bar
SA special absolute pressure range


Diaphragm material filling liquid





A stainless steel 316L


Silicone oil


C Hastelloy C


Silicone oil


X stainless steel 316L


Vegetable oil


Y Hastelloy C


Vegetable oil


Process connection


A Sanitary interface DIN 32676 DN25 / ISO 2852 DN 25
B Sanitary interface DIN 32676 DN40 / ISO 2852 DN 38
C Sanitary connection DIN 32676 DN50 / ISO 2852 DN 51


Additional option l3)


1 test report
2 Material report
3 additional 485 communication interface


Note 1: FL102 corresponds to the meter selection procedure code, FL103 corresponds to the absolute selection procedure code;
Note 2: Correspondence between process connection and applicable range:


Note A: / D additional specification selection code


Procedure connection code


M process code (first letter)


A


C, D, M, 0, F


B


C, D, M, 0, F


C


C, D, M


Chilong


ZHAOLONG ELECTRICS zhaolong


2 3 4 5


Examples of options:


Example: FL102-SDC1AA2
[FL102-S]: Sanitary Gauge Pressure Transmitter
[D]: Basic error ± 0.25%


[C1]: The journey is 0-.25bar


[A]: Wetted part is stainless steel 316L diaphragm, filling liquid is silicone oil
[A]: Sanitary interface DIN 32676 DN25 / IS02852DN25
[124]: Test report + material report + 485 communication function


Note 3: Additional options can be unselected or multi-selected.







  • No more articles
  • Next: FL102-D Gauge Pressure Transmitter
  • 24-hour consultation hotline:
    13671774687
    Home Flying Dragon Thermocouple Thermocouple products Honor technical standard Thermocouple Information Download Center Leave message contact us Sitemap xml map
    General Manager: Manager Xie Mobile: 13671774687 Address: No. 268 West Qufu Road, Shanghai Landline: 021-63811027 Fax: 021-63801621 Email: jimmy011@126.com
    © 2018 Shanghai Feilong Instrument Electric Co., Ltd. All rights reserved
    online service